Product list

ShangHai Mingwei Investment Co., Ltd.
3rd Building,No.999,Liujiang Road,Liushi Town, Yueqing Zhejiang
Tel:0577-62700899
Fax:0577-61737279
QQ£º87267135
E-mail:sh_mingwei@yahoo.cn
Website:http://www.shsiyuan.cn
Zip:325604

Product ShowCurrent£ºHome ¡ú Product Center

MS-100W

Download the PDF
Features:
Exchange the input voltage range by switches choice
Small volume, light weight, high efficiency
Protection characteristics: short circuit, overload
Air cooling
Has the boot display (light emitting diode)
100% full load and machine test
1 year the quality
Electrical specifications
Type MS-100-5 MS-100-12

MS-100-24

Output

Dc output voltage
5V 12V 24V
Output voltage tolerance
¡À1% ¡À1% ¡À1%
Rated output current
20A 8.3A 4.2A
Output current range
0-20A 0-8.3A 0-4.2A
Output power 100W 100W 101W
Ripple and the noise
80mVp-p 120mVp-p 150mVp-p
Dc voltage adjustable scope
-9%~+10% ¡À10% ¡À10%
Start, up, and keep time
500ms,20ms,24ms/230VAC.800ms,30ms,20ms/115VAC
Input
Input voltage range
90~132VAC/180~264VAC 47~63Hz(The switch choice),254~373VDC
Exchange input current
2.4A/115VAC 1.2A/230VAC
Efficiency
79% 83% 85%
Impulse current
Cold start current 35A/230VAC
Leakage current
<3.5mA/240VAC
Protection characteristics
Overload protection
Rated output power of 115% ~ 135% start over load protection
Protection way: hiccups mode, load abnormal conditions can be removed to recover
Over-voltage protection
6.2~6.8V 15~16V 30~31V
Protection way: hiccups mode, abnormal conditions can be removed to recover
Environment
Working temperature, humidit -10¡æ~+60¡æ;20%~90%RH(Please refer to reduce the specified number load curve )
Keep temperature, humidity
-20¡æ~+85¡æ;10%~95%RH No condensation
Vibrate resistance
10~500Hz,2G 10min./Cycle, duration 60 minutes, the axis
Security
Compression sex
Input/output between: 1.5KVAC Input and ground: 1.5KVAC Output and ground: 0.5KVAC
Insulation resistance
Between input and output: input and the earth, the output and the earth: 100M 0hms/500VDC
Conform to the standards Safety standards
Accord with UL1012
EMC standards
Accord with EN55022,CLASSA
Other
Weight
0.48kg 159*97*38mm (L*W*H)
Packaging
0.48kg/45pcs/22.5kg/0.9CUFT
Note: 1.All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ¡æ conditions measuring income value.
2.Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches double lines end with 0.1¦Ìand 47¦Ì when capacitance measurement.
3.Tolerance is voltage setting error, the voltage adjustment rate and the current adjust rate combined.