| Type |
LPV-30-12 |
LPV-30-24 |
LPV-30-36 |
|
Output
|
Dc output voltage |
12V |
24V |
36V |
Output voltage tolerance
|
¡À1% |
¡À1% |
¡À1% |
Rated output current
|
2.5A |
1.3A |
0.8A |
Output current range
|
0-2.5A |
0-1.3A |
0-0.8A |
Output power
|
30W |
31W |
29W |
Ripple and the noise
|
100mVp-p |
100mVp-p |
150mVp-p |
Start, up, and keep time
|
800ms,20ms,24ms/230VAC |
Input
|
Input voltage range
|
170~264VAC 47~63Hz 235~373VDC |
Exchange input current
|
0.42A/230VAC |
Efficiency
|
78% |
80% |
82% |
| Impulse current |
Cold start current 30A/230VAC |
| Leakage current |
<0.5mA/240VAC |
| Protection characteristics |
Overload protection
|
Rated output power of 105% ~ 135% start over load protection |
| Protection way: hiccups mode, load abnormal conditions can be removed to recover |
Over-voltage protection
|
The output voltage of 135% ~ 150% |
| Protection way: hiccups mode, abnormal conditions can be removed to recover |
Thermal protection
|
Internal contacts transistor temperature more than 150 ¡æ, start thermal protection |
| Protection way: cut output, the temperature is returning to normal after can be automatically restored |
Environment
|
Working temperature, humidity
|
-10¡æ~+60¡æ;20%~90%RH(Please refer to reduce the specified number load curve) |
Keep temperature, humidity
|
-20¡æ~+85¡æ;10%~95%RH No condensation |
| Vibrate resistance |
10~500Hz,2G 10min./Cycle, duration 60 minutes, the axis |
| Security |
Compression sex
|
Input/output between: 1.5KVAC |
Insulation resistance
|
Input/output between: 100M 0hms/500VDC |
| Conform to the standards |
Safety standards
|
Accord with UL1012 IP67 |
EMC standards
|
Accord with EN55022,CLASSA |
Other
|
Weight
|
0.25kg 222*30*20mm (L*W*H) |
Packaging
|
0.25kg/80pcs/21kg |
Note: 1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ¡æ conditions measuring income value. 2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches double lines end with 0.1¦Ì and 47¦Ì when capacitance measurement. 3. Tolerance is voltage setting error, the voltage adjustment rate and the current adjust rate combined. |