Product list

ShangHai Mingwei Investment Co., Ltd.
3rd Building,No.999,Liujiang Road,Liushi Town, Yueqing Zhejiang
Tel:0577-62700899
Fax:0577-61737279
QQ£º87267135
E-mail:sh_mingwei@yahoo.cn
Website:http://www.shsiyuan.cn
Zip:325604

Product ShowCurrent£ºHome ¡ú Product Center

LPV-100

Download the PDF
Features:
Rated voltage mode power supply
General international exchange full scope of the input voltage
Small volume, light weight, high efficiency
Protection characteristics: short circuit, overload, pressure, temperature
Air cooling
Meet the IP67 level
100% full load and machine test
2 years quality assurance
Electrical specifications
Type LPV-100-12 LPV-100-24

LPV-100-36

Output

Dc output voltage 12V 24V 36V
Output voltage tolerance

¡À1%

¡À1% ¡À1%
Rated output current
8.3A 4.2A 2.8A
Output current range
0-8.3A 0-4.2A 0-2.8A
Output power
100W 100W 100W
Ripple and the noise
100mVp-p 100mVp-p 100mVp-p
Start, up, and keep time
600ms,20ms,24ms/230VAC.1000ms,30ms,20ms/115VAC
Input
Input voltage range
90¡«264VAC 47¡«63Hz£¬126¡«373VDC
Exchange input current
2A/115VAC 1A/230VAC
Efficiency
80% 82% 84%
Impulse current Cold start current 35A/230VAC
Leakage current <1mA/240VAC
Protection characteristics Overload protection
Rated output power of 115% ~ 135% start over load protection
Protection way: hiccups mode, load abnormal conditions can be removed to recover
Over-voltage protection
15~17V 30~32V 42~44V
Protection way: hiccups mode, abnormal conditions can be removed to recover
Thermal protection
Shell temperature ¡Ý85¡æ£¬Start thermal protection
Protection way: cut output, the temperature is returning to normal after can be automatically restored
Environment
Working temperature, humidity
-10¡æ~+60¡æ;20%~90%RH(Please refer to reduce the specified number load curve )
Keep temperature, humidity
-20¡æ~+85¡æ;10%~95%RH No condensation
Vibrate resistance 10~500Hz,2G 10min./Cycle, duration 60 minutes, the axis
Security Compression sex
Input/output between: 1.5KVAC
Insulation resistance
Input/output between: 100M 0hms/500VDC
Conform to the standards Safety standards
Accord with UL1012 IP67
EMC standards
Accord with EN55022,CLASSA
Other
Weight
0.9kg 180*69*43mm (L*W*H)
Packaging
0.9kg/20pcs/19kg/0.9CUFT
Note: 1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ¡æ conditions measuring income value.
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches double lines end with 0.1¦Ì and 47¦Ì when capacitance measurement.
3. Tolerance is voltage setting error, the voltage adjustment rate and the current adjust rate combined.