Product ShowCurrent£ºHome ¡ú Product Center

S-1000W

Download the PDF

Features:
High reliability, low ripple
Exchange the input voltage AC200 ~ 260 V
Protection characteristics: short circuit/overload/pressure/thermal
Built-in distance open/shutdown and voltage compensation signal interface
Has the parallel function
By external 2 ~ 5 V voltage control, which can adjust the output voltage of the rated voltage of the in the range of 40% ~ 100% in value
Built-in dc electric fan forced air cooling
One year warranty
Size : 291*132*132mm £¨L*W*H£©

model

output

Dc output voltage

12V

15V

24V

48V

Output voltage tolerance

¡À1%

¡À1%

¡À1%

¡À1%

Rated output current

83A

67A

42A

12A

Output current range

0-83A

0-67A

0-42A

0-12A

Output power

1000W

1000W

1000W

1000W

Ripple and the noise

150mVp-p

150mVp-p

240mVp-p

480mVp-p

Dc voltage adjustable scope

+ 5%; By external 2 ~ 5 V voltage control, which can adjust the output voltage of the rated voltage of the in the range of 40% ~ 100% in value

Start, rise, keep time

200ms, 100ms, 20ms Loaded with

input

Input voltage range

90¡«130VAC / 180¡«260 VAC47¡«63 Hz£»The switch choice
260¡«370VDC

Exchange input current

13A/115 VAC 8.0A/ 230 VAC

efficiency

80%

81%

85%

87%

Impulse current

50A/230V

Leakage current

3.5 mA/240VAC

Protection characteristics

Overload protection

110%¡«135%

Protection way: current limiting, delay shut off, restart

Overvoltage protection

110%~135%

Protection way: cut output, restart

High temperature protection

TSW1 (power tube) temperature > 100 ¡æ, restart when cut off output

environment

Working temperature, humidity

-10¡æ¡«+65¡æ£¬20%¡«90 %RH

Keep temperature, humidity

-20¡æ¡«+85¡æ£¬10%¡«95 %RH

Vibrate resistance

10 ~ 200 Hz ac, 2 G 10 min. / 1 cycle time, 60 minutes, the axis

security

Compression sex

I/P-O/P, I/P-FG:1500VAC

Insulation resistance

I/P-O/P, I/P-FG, >100M Ohms / 500VDC

Standards

Safety standards

Accord with
  UL1950,CSA22.2,IEC60950

EMC standard

Accord with
  FCC Part 15 Class A

Other

weight

4.5Kg;

packaging

4pcs/20kg/CARTON

note

1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ¡æ conditions measuring income value.

2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.

3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.

4. The power to consider as a device installed in final equipment, this equipment must be to make sure it¡¯s EMC index.