Features: Input voltage range had exchange by switch choice Had small volume, light weight, high efficiency Characteristics: short circuit protection miscalculates/overload Had natural cooling With that took on light emitting diode (led) 1 0, 0% had burned machine full load test 1 years had quality guarantee Size: had 159 x 97 x 38 mm
| |
|
model
|
MS-120-12 |
MS-120-15 |
MS-120-24 |
output
|
Dc output voltage
|
12V |
15V |
24V |
|
Output voltage tolerance
|
¡À1% |
¡À1% |
¡À1% |
|
Rated output current
|
10A |
8A |
5A |
|
Output current range
|
0-10A |
0-8A |
0-5A |
|
Output power
|
120W |
120W |
120W |
|
Ripple and the noise
|
100mVp-p |
120mVp-p |
150mVp-p |
|
Dc voltage adjustable scope
|
-9%¡«+10% |
¡À10% |
¡À10% |
|
Start, rise, keep time
|
600ms,20ms,24ms/230VAC.1000ms,30ms,20ms/115VAC |
input
|
Input voltage range
|
90¡«132VAC/180¡«264VAC 47¡«63Hz(The switch choice)£¬254¡«373VDC |
|
Exchange input current
|
2.8A/115VAC 1.4A/230VAC |
|
efficiency
|
82% |
83% |
85% |
|
Impulse current
|
Cold start current 35A/230VAC |
|
Leakage current
|
£¼3.5mA/240VAC |
Protection characteristics
|
Overload protection
|
Protection way: hiccups mode, load abnormal conditions can be removed recovery
|
environment
|
Working temperature, humidity
|
-10¡æ¡«+60¡æ;20%¡«90%RH(Please refer to reduce the specified number load curve) |
|
Keep temperature, humidity
|
-20¡æ¡«+85¡æ;10%¡«95%RH No condensation
|
|
Vibrate resistance
|
10¡«500Hz£¬2G 10min./ 1 cycle time, 60 minutes, the axis
|
security
|
Compression sex
|
Input/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5: 0.5KVAC |
|
Insulation resistance
|
Between the input and output, the output and input: with ground: 100M Ohms/500VDC |
| standards |
Safety standards
|
Accord with UL1012 |
|
EMC standard
|
Accord with EN55022£¬CLASSA |
other
|
weight
|
0.48kg 159*97*38£¨L*W*H£© |
|
packaging
|
0.48kg/45pcs/22.5kg/0.9CUFT |
note
|
1. All the parameters in has not specified, all is in 2 3 0 V voltage input, A C rated load and 2 5 ¡æ conditions measuring income value. 2. Ripple and noise voltage is in 2 0 M H z bandwidth with 1 to 2 inches oscilloscope twisted pair end and 0. 1 mu and 4 7 muon capacitance measurement when. 3. Tolerance is voltage error, electricity set
|