| Type |
SF-75-5 |
SF-75-12 |
SF-75-24 |
| Output |
Dc output voltage
|
5V |
12V |
24V |
Output voltage tolerance
|
¡À1% |
¡À1% |
¡À1% |
Rated output current
|
15A |
6.3A |
3.2A |
Output current range
|
0-15A |
0-6.3A |
0-3.2A |
Output power
|
75W |
76W |
77W |
Ripple and the noise
|
80mVp-p |
100mVp-p |
120mVp-p |
Dc voltage adjustable scope
|
-9%¡«+10% |
¡À10% |
¡À10% |
Start, up, and keep time
|
600ms,30ms,24ms/230VAC.1000ms,30ms,20ms/115VAC |
Input
|
Input voltage range
|
90¡«264VAC 47¡«63Hz or 120¡«373VDC |
Exchange input current
|
1.5A/115VAC 0.75A/230VAC |
Efficiency
|
79% |
82% |
84% |
Impulse current
|
Cold start current 40A/230VAC |
Leakage current
|
£¼3.5mA/240VAC |
Protection
characteristics
|
Overload protection
|
Rated output power of 110%~150% start over load protection |
| Protection way: hiccups mode, load abnormal conditions can be removed to recover |
Over-voltage protection
|
6.2¡«6.8V |
15¡«16V |
30¡«31V |
| Protection way: hiccups mode, abnormal conditions can be removed to recover |
Environment
|
Working temperature, humidity
|
-10¡æ¡«+60¡æ;20%¡«90%RH(Please refer to reduce the specified number load curve) |
Keep temperature, humidity
|
-20¡æ¡«+85¡æ;10%¡«95%RH No condensation |
Vibrate resistance
|
10¡«500Hz£¬2G 10min./1Cycle, duration 60 minutes, the axis |
Security
|
Compression sex
|
Input/output between:
1.5KVAC Input and ground:1.5KVAC Output and ground:
0.5KVAC |
Insulation resistance
|
Input/output between:Input and the earth, the output and the earth:
100M Ohms/500VDC |
Conform to
the standards
|
Safety standards
|
Accord with UL1012 |
EMC standards
|
Accord with EN55022£¬CLASSA |
Other
|
Weight
|
0.4kg 129*97*38£¨L*W*H£© |
Packaging
|
0.4kg/45pcs/19kg |
Note
|
1. All the parameters in has not specified, all is in 230VAC voltage input, rated load and 25¡æ conditions measuring income value
¡£
2. Ripple and noise voltage is in 20MHz bandwidth with 12 inches oscilloscope twisted pair end and 0.1¦Ìand 47¦Ìcapacitance measurement when.
3. Tolerance is voltage setting error, the voltage adjustment rate and the current adjust rate combined. |